EFFECT OF DIFFERENT POLYMERIZATION DEVICES ON THE SHEAR BOND STRENGTH BETWEEN DIFFERENT METALS AND AN INDIRECT RESIN
Abstract
Purpose: To evaluate the effect of different polymerization units on the shear bond strength between different metals and a laboratorial resin. Method: Sixty metallic cylinders were obtained (5mm x 4mm), thirty in commercially pure titanium (CpTi) and thirty in gold-palladium alloy (Au-Pd), which were sandblasted (Al2O3 110µm, 20s, 2,9 bar) before the resin application. Two layers of opaque (Sinfony Opaque) were applied with a brush and with the assistance of the teflon matrix, the esthetic veneering resin was applied on the metallic cylinders. The opaque and veneering resin were polymerized at different polymerized, according to experimental groups: GrA1 – CpTi + Visio Beta (3M ESPE/EUA); GrA2 – CpTi + Powerlux (EDG, Brazil); GrA3 – CpTi + Strobolux (EDG, Brasil); GrB1 – Au-Pd + Visio Beta; GrB2 – Au-Pd + Powerlux; GrB3 – Au-Pd + Strobolux. The specimens were submitted to shear test in a universal testing machine (model DL/1000-EMIC) with a 500kg load cell (0,5 mm/min). The data (MPa) were submitted to the analysis of variance (ANOVA) and tukey’s test (5%). Results: The means and standard deviations obtained were (MPa): GrA1: 6.1±1.9; GrA2: 5.6±1.4; GrA3: 5.5±2.5; GrB1: 9.4±2.5; GrB2: 7.4±2; GrB3: 8.2±3.1. Only the principal factor “metal” (p=0.0001<0.05) presents statistical significance (Au-Pd=8.39 MPa, Ticp= 5,7 MPa). The “polymerized units” (p=0,2062>0.05) did not influenced the bond strength between resin and metal (VisioBeta= 7,8 MPa; Powerlux=6,6 MPa; Strobolux=6,8 MPa). Conclusion: The Au-Pd alloys promote higher bond strength to sinfony indirect resin compared to Ticp, regardless the polymerized unit used. Descriptors: shear bond strength; commercially pure titanium; Au-Pd alloy; indirect resin; polymerized unit.Downloads
Published
2010-10-29
Issue
Section
Research
License
Eu (Nós), abaixo assinado(s) transfiro(erimos) todos os direitos autorais do artigo intitulado (título) à Revista Brasileira de Ciências da Saúde - RBCS. Declaro(amos) ainda que o trabalho é original e que não está sendo considerado para publicação em outra revista, quer seja no formato impresso ou no eletrônico. Temos ciência de que a revista se reserva o direito de efetuar nos originais alterações de ordem normativa, ortográfica e gramatical com vistas a manter o padrão culto da língua, respeitando, contudo, o estilo dos autores e que os originais não serão devolvidos aos autores. (Completar com a Declaração de Ausência/Presença de Conflitos de Interesse)How to Cite
Abreu, C. W., Souza, R. O. A., Passos, S. P., Vásquez, V. Z., & Bottino, M. A. (2010). EFFECT OF DIFFERENT POLYMERIZATION DEVICES ON THE SHEAR BOND STRENGTH BETWEEN DIFFERENT METALS AND AN INDIRECT RESIN. Revista Brasileira de Ciências Da Saúde, 14(1), 85-92. https://periodicos.ufpb.br/index.php/rbcs/article/view/4573