REMOVAL OF NITROGEN AND ORGANIC MATTER IN AN INTERMITTENTLY AERATED HORIZONTAL SUBSURFACE FLOW CONSTRUCTED WETLAND
DOI:
https://doi.org/10.4090/juee.2020.v14n2.175-181Keywords:
Constructed wetland, intermittent aeration, nitrogen removal, COD removal.Abstract
The objective of this work was to evaluate the effect of intermittent aeration on the removal of ammonium (NH4+), total nitrogen (TN) and chemical oxygen demand (COD) in a horizontal subsurface flow constructed wetland (HFCW). Two HFCWs were studied, one non-aerated and another aerated intermittently, and both cultivated with Typha latifolia. Each system received 8.6 L day-1 of synthetic wastewater, resulting in 3 days of hydraulic retention time. The two systems displayed high efficiencies in the removal of COD (>90%); however, the intermittently aerated HFCW showed a higher rate of COD removal. Additionally, the removal of TN (48.8%) and NH4+ (57.7%) in the non-aerated system was limited, while in the aerated system, the efficiencies of TN (81.2%) and NH4+ (98.6%) removal were satisfactory. Thus, the results indicate that via intermittent aeration, nitrification and denitrification occur simultaneously, improving the performance of HFCW in the removal of TN and NH4+.Downloads